145 - MiTo   1.4 16v TJet   PARKING SENSOR CONTROL UNIT CONNECTOR - R.R.   5590H05   

Detail     Detail

Removing ( Refitting )

- Disconnect the negative battery terminal or, for cars equipped with the Start&Stop system, the "negative dummy pole".

 

 

Name

 

Connector

 

-

 

BATTERY

 

   See A001 BATTERY

 

-

 

TERMINAL BOX

 

   See A005 Contact board

   Op. 7040H80 REAR PARCEL SHELF - R.R.

- Open the tailgate.


Enlarge the image


1. Working under the left support for the rear parcel shelf, undo the screws (1a) securing the control unit.

2. Extract the control unit (2b) through the housing (2a).

3. Move the electrical connection protections.

4. Disconnect the electrical connections (4a) and (4b) for the control unit.

 

 

Name

 

Connector

 

4

 

PARKING SENSOR CONTROL UNIT

 

   See M084 PARKING SENSOR CONTROL UNIT


Enlarge the image


1. Remove the block (1a) from the internal connection using a screwdriver (1b), working on the retaining tabs (1c).


Enlarge the image


1. Extract the cables (1a) from the connector using the tool (1b).

 

Tool

 

Name

 

Function

 

Validity

 

2.000.018.605

 

Extractor

 

Terminal extractor

 

- To replace the terminals proceed as follows.

These illustrations only refer to replacing an individual terminal for the connector block illustrated, but are valid for all families of connectors. If several terminals are being replaced, make offset junctions between them in order to restrict the size of the cable loom and thereby facilitate the subsequent refitting in the sheath.


Enlarge the image


1. Release the cable for the terminal to be replaced sufficiently to work and cut at the midway point as illustrated in the figure.


Enlarge the image


1. Measure the cable that has just been cut (1a), then cut the replacement cable (1b) 15 mm longer than the cable to be replaced.


Enlarge the image


1. Strip the new replacement cable (1a) and the corresponding wiring cable (1b) for a maximum length of 10 mm.

To avoid cutting the strands and losing part of the cable conduction powers, it is advisable to expose the cables carefully.


Enlarge the image


1. Fit the thermal restricting coupling tube (1a) on the wiring cable. Starting as illustrated in the figure (1b) twist the strands (1c), then move the coupling tube (1a) until the coupling is covered with the tin ring (1d) by the twisted strands (1c).

A. Thermal shrinking coupling tube

B. Adhesive ring

C. Tin ring

D. Twisted strands


Enlarge the image


1. Using the drier (1a) fitted with the heat shield (1b) heat the thermal shrinking tube (1c) until the tin ring (1d) melts as illustrated in figure (1e).

Wait for the tin to cool down, then refit the wiring.

 

Tool

 

Name

 

Function

 

Validity

 

2.000.029.200

 

Sheet

 

Heat shield sheet

 

Take great care not to get the cables to be joined dirty as this will adversely affect the continuity of the electrical conduction. While heating the thermal shrinking tube, as a result of the high temperatures reached, the drier and the heat shield must not, under any circumstances, come into contact with clothes or other compartments.

The drier used in this procedure is commercially available.

Refitting ( Removing )

- Fit the terminals in the connector block checking that the retaining tabs are secured.

- Slightly pull every single cable checking that the terminals are secured correctly.

- Reposition the safety slit for the connector.

- Fit the internal connection in the connection block and engage the retaining tabs.

- Connect the electrical connections from the control unit.

- Fit the protections for the electrical connections.

- Position the control unit.

- Do up the screws.

   Op. 7040H80 REAR PARCEL SHELF - R.R.

- Connect the negative battery terminal or the "negative dummy pole".

- Check the operation of the device.