145 - MiTo   1.4 16v TJet   RUMOROSITÀ NEL VANO MOTORE PROVENIENTE DALLA TUBAZIONE ARIA PULITA   S143   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

NOISE IN ENGINE COMPARTMENT CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Engine compartment

 

Carry out a road test to check whether, by accelerating progressively in third gear up to 3500 rpm, noise is present in the engine compartment

 

End of diagnosis

 

Noise in the engine compartment

 

Go to Step 2

 

2

 

COMPONENT CONCERNED

 

CHECK CLEAN AIR PIPE ATTACHMENT

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Clean air pipe attachment

 

Check if the bands are correctly closed.

Attachments intact. Support brackets intact.

 

Go to Step 3

 

1. Attachments not correct

2. Attachments broken

 

1. Restore correct fastenings

2. Replace the clean air pipes

 Op. 1048A54 SLEEVE TO TURBOCHARGER - R R

 

3

 

COMPONENT CONCERNED

 

CHECK THAT CLEAN AIR LINE IS INTACT

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Clean air intake pipelines

 

Check that the piping is intact and for he presence of bleed/excessive play in the coupling area:

- clean air pipes/filter box

- clean air sleeve/turbocharger or throttle body

 

Go to Step 4

 

Presence of bleed in the coupling areas shown.

 

Restore the tightening of the fastenings where there is leakage/looseness; carry out a test on the car to make sure that the fault has disappeared.

 

4

 

COMPONENT CONCERNED

 

CHECK AIR CIRCULATION PIPE INTEGRITY

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Air delivery pipes

 

Check for a bleed in the air delivery pipes.

 

Go to Step 5

 

Presence of a bleed in the air delivery pipes.

 

Replace any damaged components of the air delivery pipes if there are holes.

 

5

 

COMPONENT CONCERNED

 

CHECK AIR CIRCULATION PIPE CONNECTIONS AND EXTENSION INTEGRITY

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Air delivery pipes

 

Check for bleeds in the pipe junction/connection area (ex. blow-by, canister, etc.)

 

Go to Step 6

 

Presence of bleeds in the piping junction/connection areas

 

Replace the damaged pipe

 

6

 

COMPONENT CONCERNED

 

CHECK THE CORRECT BAND CLOSING ARE THEIR PRESENCE ON THE BLOW BY PIPING

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Blow-by pipe

 

Dismantle the blow by pipe to check for any oil and check the band closing.

 

Go to Step 7

 

Oil leakage on the clean air connection pine side/band not correctly closed

 

Close the bands correctly and eliminate oil in the clean air pipe

 

7

 

COMPONENT CONCERNED

 

CHECK INTEGRITY OF BLOW BY PIPES

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Blow-by pipe

 

Dismantle the blow by pipe and check it is intact

 

End of diagnosis

 

Presence of cracks/ damage in the pipe

 

Replace the blow by pipes