145 - MiTo   1.4 16v TJet   ENGINE HEATER FAN NOISE/VIBRATION   S131   


 

 

TEST RESULTS

 

1

 

FAN OPERATION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

With the engine on and engine temperature approximately 90°, or as an alternative, activating the compressor (A/C version), check fan activation, and verify the fault

 

End of diagnosis

 

Noise upon activation of the fan

 

Go to Step 2

 

2

 

FOREIGN BODIES CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check for foreign bodies next to the fan that cause noise

 

Go to Step 3

 

Foreign bodies identified next to the fan

 

Remove the foreign bodies causing the noise

 

3

 

COOLING MODULE FASTENING CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check for the presence of looseness on the fastenings/screws of the duct on the cooling module

 

Go to Step 4

 

Looseness on the fastenings of the cooling module

 

Restore the fastenings of the duct on the cooling module

 

4

 

COOLING MODULE INTERFERENCE CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check whether the fan impeller is still noisy after the previous interventions

 

Go to Step 5

 

The impeller is still noisy

 

Replace the impeller assembly

 Op. 1088B26 AIR DUCT ON RADIANT MASS - R.R.

 

5

 

NOISE/VIBRATIONS CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Disconnect the fan connector and check whether the noise/vibration disappears.

 

End of diagnosis

 

The noise persists

 

Go to Step 6

 

6

 

NOISE/VIBRATIONS CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check water pump noise with the engine fan disconnected.

 

End of diagnosis

 

Water pump noise

 

Replace the water pump

 Op. 1088C10 WATER PUMP - R.R.