145 - MiTo   1.4 16v TJet   COMANDO DISTRIBUZIONE/MISCELAZIONE NON FUNZIONANTE   L054   


 

 

TEST RESULTS

 

1

 

DISTRIBUTION AND MIXING FLAP OPERATION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check that the distribution and mixing flaps are working correctly

 

Go to Step 2

 

Distribution or mixing flaps damaged or not working correctly

 

Replace the flaps that do not work properly

 Op. 5040D44 AIR CONDITIONER RIGHT AIR MIXER FLAP CONTROL LINKAGE/MECHANISM - R.R.

or

 Op. 5040D51 A/C SYSTEM LEFT AIR DISTRIBUTION FLAP LINKAGE/GEAR - R.R.

 

2

 

BOWDEN CABLE OPERATION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check that the Bowden cables are working correctly; specifically check that there are no wrong paths of the Bowden cable.

 

Go to Step 3

 

Bowden cable not positioned correctly

 

Reposition the Bowden cable correctly or replace it if necessary

 

3

 

MIXING/DISTRIBUTION KNOB CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check if there is any damage on the mixing or distribution knobs

 

End of diagnosis

 

Knobs damaged or not working correctly

 

Replace the faulty knob

 Op. 5040D23 KNOB (ONE) FOR ANY OF THE AIR CONDITIONING CONTROLS - R.R.