145 - MiTo   1.4 16v TJet   CLIMATE CONTROL SYSTEM COMPRESSOR OPERATION FAILED   L049   


 

 

TEST RESULTS

 

1

 

CHECK USING DIAGNOSIS EQUIPMENT

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Connect the diagnosis equipment to the climate control system control unit and check for the presence of errors on:

  • frost sensor

  • outside temperature sensor

 

Go to Step 2

 

Presence of errors on the frost sensor or on the outside temperature sensor

 

Proceed as instructed by the diagnosis equipment

 

2

 

CLIMATE CONTROL SYSTEM CONTROL UNIT CONNECTION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

With engine off, remove the control unit from the dashboard support and disconnect the cable connector from the control unit. Reattach the connectors and check that connections are correct, identifying any poor contact

 

Go to Step 3

 

Fault on the climate control system control unit connections

 

Restore the correct connections

 

3

 

CLIMATE CONTROL SYSTEM GAS CHARGE CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check that the climate control system gas charge is correct

 

End of diagnosis

 

Climate control system gas charge insufficient

 

Restore the correct climate control system gas charge