145 - MiTo   1.4 16v TJet   COMPRESSORE INEFFICIENTE/ECCESSO DI OLIO NELL'IMPIANTO    L038   


 

 

TEST RESULTS

 

1

 

GAS CHARGE CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

With vehicle's engine idling and compressor on, check that the gas charge quantity is correct

 

Go to Step 2

 

Gas charge not correct

 

Restore the correct gas charge

 

2

 

COOLANT GAS CIRCUIT LEAKAGE CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

With vehicle's engine running, climate control system on and passenger compartment heater fan at max. speed (compressor button ON), position the air adjustment knob/button at max. cold, and check for any leakage.

 

End of diagnosis

 

Leakage found in the circuit

 

Go to Step 3

 

3

 

CLIMATE CONTROL SYSTEM O-RING CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Withdraw the pipes from the compressor and make sure that the O-rings on the pipes are correctly positioned; specifically check whether there has been pinching.

 

Go to Step 4

 

O-ring seal failure

 

Replace the O-rings and refit the pipes on the compressor

 

4

 

PIPES/EVAPORATOR/EXPANSION VALVE CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check if there is a localised leakage on other components of the cooling system, specifically other pipes of the gas system or the evaporator/expansion valve

 

Go to Step 5

 

Leakage detected on the examined components

 

Restore the seal of the components on which the leakage has been detected and, if necessary, replace them.

 

5

 

CONDENSER CONDITION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check that the condenser is clean (mud, foreign bodies...)

 

End of diagnosis

 

Presence of dirt or foreign bodies on the condenser

 

Restore correct operation of the condenser