145 - MiTo   1.4 16v TJet   COMANDO PRESA ARIA RICIRCOLO NON FUNZIONANTE/BLOCCATO   L029   


 

 

TEST RESULTS

 

1

 

CHECK THE OPERATION OF THE RECIRCULATION AIR INTAKE FLAP

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Access to the air intake area on the assembly and to the climate control, release the Bowden cable and check if the operation on control side is ok

 

End of diagnosis

 

The control is locked

 

Go to Step 2

 

2

 

CLIMATE CONTROL UNIT OPERATION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check whether there are ovalised wheels or levers or other forming problems in the climate control unit gears

 

Go to Step 3

 

Identify any faults on the levers or on the wheels

 

Replace the faulty components of the climate control system

 

3

 

CLIMATE CONTROL SYSTEM CONTROL OPERATION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Manually check the movement of the recirculation flap

 

Go to Step 4

 

Recirculation flap locked

 

Replace the faulty gears behind the control, restoring correct operation

 

4

 

CLIMATE CONTROL SYSTEM CONTROL OPERATION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check the integrity of the installed gears and the correct positioning of the latter.

 

Go to Step 5

 

In case of breaks, printing faults and strains

 

Replace the faulty components.

 

5

 

CHECK THE CONDITIONS OF THE RECIRCULATION AIR INTAKE FLAP

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check if the air intake flap is damaged or doesn't operate properly

 

End of diagnosis

 

Air intake flap broken or not properly operating

 

Replace the recirculation air intake flap