145 - MiTo   1.4 16v TJet   MIXING ACTUATOR NOT WORKING   L023   


 

 

TEST RESULTS

 

1

 

ACTUATOR OPERATION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Connect the diagnosis equipment to check whether there are error codes consistent with a fault related to an actuator malfunction.

 

End of diagnosis

 

Faults related to actuator malfunction have been identified

 

Go to Step 2

 

2

 

ACTUATOR CONNECTIONS CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check whether the electrical wiring connections are loose. Detach/reattach the connection on the actuator side and on the control support side. Check whether the error is still present

 

End of diagnosis

 

The fault occurs again

 

Go to Step 3

 

3

 

ACTUATOR MOBILITY CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check the operation activating the function that the actuator should carry out manually. With the engine running, switch on the passenger compartment heater fan at the maximum speed and place the flaps in the various distribution positions using the control/control unit (in manual mode). Check the air flow in the passenger compartment by placing your hand on the vents.

 

End of diagnosis

 

The recirculation actuator is not working correctly

 

Go to Step 4

 

4

 

CHECK FOR THE PRESENCE OF BLOCKAGES ON THE MIXING ACTUATOR

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check whether there is a mechanical blockage/breakage of the flaps in the mixing actuator

 

Go to Step 5

 

Presence of mechanical blockages on the mixing actuator

 

Remove the mechanical blockages/Replace the actuator

 Op. 5040D84 AIR CONDITIONING LEFT AIR MIXTURE FLAP CONTROL MOTOR - R.R

or

 Op. 5040D86 AIR CONDITIONING RIGHT AIR MIXTURE FLAP CONTROL MOTOR - R.R

 

5

 

PASSENGER COMPARTMENT HEATER OPERATION CHECK

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check that the passenger compartment heater is working correctly

 

Go to Step 6

 

The passenger compartment heater is not working correctly

 

Restore correct operation of/replace the passenger compartment heater

 Op. 5040C54 AIR CONDITIONING HEATER RADIATOR - R+R WITH AIR CONDITIONING CASING REMOVED

 

6

 

CHECK OPERATION OF THE CLIMATE CONTROL SYSTEM CONTROL UNIT

 

EVERYTHING OK

 

PROBLEMS ENCOUNTERED

 

OPERATION

 

 

Check operation of the climate control system control unit

 

End of diagnosis

 

The climate control system control unit is not working correctly

 

Replace the climate control unit

 Op. 5040D15 CONTROL UNIT WITH KNOBS AND BUTTONS FOR DUAL ZONE AIR CONDITIONER - R.R.