Removing
(
Refitting
)
Op. 5040C51 WATER SUPPLY PIPE TO AIR CONDITIONING HEATER - R.R. WITH AIR CONDITIONING CASING REMOVED |
![]() |
![]() |
![]() ![]() |
1. Disconnect the electrical wiring (1a) from the retainer (1b) and from the cable duct (1c). 2. Unscrew the bolts. |
![]() ![]() |
1. Working on the left side of the air conditioning casing, release the retainer using a screwdriver. 2. Separate the half-casing with the evaporator (2a) from the middle half-casing (2b) releasing the lower retainer (2c). |
![]() ![]() |
1. Keep the half-casing (1a) complete with evaporator (1b). |
|
- If necessary, separate the following components: Op. 5040C18 RECIRCULATION AIR INTAKE UNIT - R.R WITH AIR CONDITIONING CASING REMOVED |
![]() |
![]() |
Op. 5040B32 EXPANSION VALVE (ORIFICE TUBE) R.R. WITH AIR CONDITIONING CASING REMOVED |
![]() |
|
Refitting
(
Removing
)
- Check that the evaporator is intact and not leaking and does not show signs of damage or deposits of dirt on the finned surface. - Refit the components if they have been removed: Op. 5040B32 EXPANSION VALVE (ORIFICE TUBE) R.R. WITH AIR CONDITIONING CASING REMOVED |
![]() |
![]() |
Op. 5040C18 RECIRCULATION AIR INTAKE UNIT - R.R WITH AIR CONDITIONING CASING REMOVED |
![]() |
- Position the half-casing complete with evaporator on the middle half-casing and attach the lower retainer. - Working on the left side of the air conditioning casing, attach the retainer. - Working on the right side of the air conditioning casing, attach the retainer. - Connect the wiring retainers. - Connect the electrical connections for the motors. - Fit the temperature sensor and attach the tab and the retainers. - Screw in the bolts. - Connect the electrical wiring to the retainer and to the cable duct. |
![]() |
Op. 5040C51 WATER SUPPLY PIPE TO AIR CONDITIONING HEATER - R.R. WITH AIR CONDITIONING CASING REMOVED |
![]() |