145 - MiTo   1.4 16v TJet   AIR CONDITIONING SYSTEM OPERATION CHECK (PRESSURE)   5040OB   


Do not check the air conditioning system in the immediate vicinity of the walls (distance of approximately 2 m) in order to ensure sufficient circulation of air around the condenser.

 

STEP

 

CHECK TO BE PERFORMED

 

REMEDIAL ACTION IF THE CHECK IS OK

 

1

 

Connect the air conditioning system repressurizing station.

Read the value on the high pressure gauge and compare it with the A/C (air conditioning) pressure parameter, checking that the two values more or less coincide.

 

Carry out

   See Test 5040BC CHECK ON CLIMATE CONTROL COMPRESSOR ACTIVATION/DEACTIVATION FROM LINEAR SENSOR

 

2

 

Check that the condenser is not blocked with dirt

 

Clean the condenser fins or repair the radiator

 

3

 

Carry out the

   See Test 5040AB REFRIGERANT CIRCUIT CHECK