Disconnect the electrical connector for the mixture actuator See N078 LEFT MIXED AIR FLAP ACTUATOR See N079 RIGHT MIXED AIR FLAP ACTUATOR See N112 RIGHT AIR DISTRIBUTION ACTUATOR See N113 LEFT AIR DISTRIBUTION ACTUATOR or distribution actuator (depending on which is one end) and supply it directly with a 12 V battery, connecting the positive battery pole to pin 5 and the negative one to pin 6. Check that with the power supply like that the actuator turns. If this does not happen, reverse the polarity at pins 5 and 6 and check that the actuator turns in one direction. Place the actuator in the end of travel position, then reverse the polarity and place it in the opposite end of travel position. Repeat this test at least twice, checking that the actuator completes the travel in both directions without problems. If there are problems with the travel, check that they are not due to the presence of mechanical impediments or interference. If this is the case, eliminate them and repeat the test. Connect the diagnostic equipment in ohmmeter mode between pins 1 and 3 of the actuator and check that the resistance is between 3.76 and 5.64 Ohm. Connect the diagnostic equipment ohmmeter mode between pins 1 and 2 of the actuator and check that the resistance measured varies continuously during the actuator travel. |