145 - MiTo   1.4 16v TJet   CLIMATE CONTROL RECIRCULATION NOT WORKING   L016   


 

 

 

Test results

 

1

 

CLIMATE CONTROL NODE CORRECT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

When the vehicle engine is running, set the climate control system control unit to AUTO, operate the temperature knob to 22°C, set the fan speed to 8 bars and then press the recirculation key (check that the recirculation symbol appears on the display). Then feel the changes in air flow during flap opening/closure. Also locate the grille in the engine compartment for the air intake casing and check the air intake when switching from recirculation to outside air intake.

When the control unit is set to the FULL AUTO function and the outside temperature is below 3°C the air intake flap opens automatically to prevent the windscreen from misting up

 

Move on to Step 2

 

1. The recirculation symbol does not appear on the display

2. The recirculation symbol appears on the display (but the recirculation does not work)

 

1. Move on to Step 3

2. Move on to Step 2

 

2

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Connect the Examiner diagnostic equipment and check:

- that there are no errors at the air recirculation actuator

 

Move on to Step 6

 

Errors in the recirculation actuator.

 

Move on to Step 3

 

3

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Keeping the Examiner diagnostic equipment connected, check, through active diagnosis,

- the correct operation of the air recirculation actuator

- correct activation of all the graphic LCD symbols in the display

 

Move on to Step 6

 

1. Air recirculation actuator not working

2. The recirculation symbol does not come on

 

1.Move on to Step 4

2.Replace the climate control system control unit

 Op. 5040D15 CONTROL UNIT WITH KNOBS AND BUTTONS FOR DUAL ZONE AIR CONDITIONER - R.R.

 

4

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check whether the electrical wiring connections are loose.

Remove the control unit from the panel mounting, disconnect the wiring connector from the control unit, check visually for any damage to the connector and reconnect correctly to check for false contacts.

Remove the oddments pocket and disconnect the connector, inspecting visually for any damage to it and reconnect the electrical connector to the actuator

 

Move on to Step 5

 

1. Electrical wiring connections loose or damaged

 

Renew the correct electrical connections

 

5

 

CORRECT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Then proceed as follows: with the engine running, switch on the recirculation air intake function manually with the fan at the maximum speed. If the actuator works and the flap is driven, feel to check whether the air flow rate varies during the movement. Deactivate the function by returning the actuator to its original condition. Identify the air intake casing grille on the vehicle and check the air intake in the shift from recirculation to outside air and the other way round by feeling with your hand.

If the result of the check is positive, do not replace the actuator. If there are further doubts as to the operation of the actuator, it is possible to carry out the check following the instructions described below if the air intake casing is easily accessible.

 See Test 5040DE SEQUENTIAL PROCEDURE FOR CHECKING RECIRCULATION ACTUATOR OPERATION

 

Move on to Step 6

 

Incorrect operation of recirculation actuator

 

Replace the recirculation actuator

 Op. 5040D75 AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R

 

6

 

RECIRCULATION FLAP TRAVEL CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Visually inspect that the air recirculation flap completes its travel without any hinderance

 

End of diagnosis

 

1. Flap travel incomplete

2. Kinematic components/toothed wheels damaged

 

1. Free the air recirculation actuator flap from the impediment

2. Restore the correct operation of the recirculation kinematic components

The recirculation function does not work when the special button in the switch panel is pressed.