145 - MiTo   1.4 16v TJet   VEHICLE PROTECTION SYSTEM WARNING LIGHT OFF (INITIAL TEST NOT CARRIED OUT)   K136   


 

 

 

Test results

 

1

 

ERROR CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of one or more of the following errors using the Examiner in Instrument Panel Node mode:

- CAN line

- EEPROM memory

 

Move on to Step 2

 

1. "No additional information" and/or "BUS off" detected

2. Fault in EEPROM memory

 

1. Continue as instructed by the diagnostic equipment

2. Replace the instrument panel

 

2

 

ACTIVE DIAGNOSIS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Use the Examiner to check the Autotest function is correctly activated in Active Diagnosis mode

 

Move on to Step 3

 

The function in question is not controlled by Active Diagnosis

 

Replace the instrument panel

 Op. 5560B10 CONTROL PANEL - R+R

 

3

 

CORRECT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the fault is no longer present

 

End of diagnosis

 

The fault persists

 

Contact the Service Department for further information on the problem