145 - MiTo   1.4 16v TJet   INSTRUMENT PANEL NOT WORKING   K095   


 

 

 

Test results

 

0

 

PRELIMINARY CHECKS

 

All OK

 

Problems encountered

 

Operation

 

 

Connect an EXAMINER and check the following at CAN INFORMATION:

- No control units inactive

- No faulty control units

- No control units with faulty CAN

 

Move on to Step 1

 

1. Error at CAN

2. Communication with the Body Computer impossible

 

1. Continue following the instructions given by the diagnostic equipment

2. Move on to Step 5

 

1

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Using the Examiner in the Instrument Panel Node mode, check that there are no errors and that the parameters are present

 

Move on to Step 4

 

1. Errors present

2. Communication with the instrument panel impossible

 

1. Continue following the instructions on the diagnostic instrument

2. Move on to Step 2

 

2

 

ELECTRICAL POWER SUPPLY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the electricity supply to the Instrument Panel Node is correct

 See E4010 INSTRUMENT PANEL

 

Move on to Step 3

 

Fault in positive electrical power supply and/or earth

 

Replace the defective component (in the case of a fuse, find out what caused it to blow)

 

3

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the electrical connections between the Body Computer and Instrument Panel, in particular, check that each individual pin is properly connected.

 

Move on to Step 4

 

Electrical connections not working

 

Restore the damaged electrical connections

 

4

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Using an Examiner check, in Body Computer Node mode, that there are no errors

 

Move on to Step 7

 

1. Impossible to connect to the Body Computer control unit

2. Errors present

 

1. Move on to Step 5

2. Continue following the instructions on the diagnostic instrument

 

5

 

ELECTRICAL POWER SUPPLY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the Body Computer power supply is correct

 

Move on to Step 6

 

Fault in positive electrical power supply and/or earth

 

Replace the defective component (in the case of a fuse, find out what caused it to blow)

 

6

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Use an Examiner to check the possibility of connection to the Body Computer Node

 

Move on to Step 7

 

Impossible to connect to the Body Computer control unit

 

Replace the Body Computer

 Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.

 

7

 

CORRECT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the fault is no longer present

 

End of diagnosis

 

The fault persists

 

Replace the Instrument Panel

 Op. 5560B10 CONTROL PANEL - R+R

With the ignition ON, some of the warning lights are not timed and the instruments are not working with the engine running.