145 - MiTo   1.4 16v TJet   INSTRUMENT LIGHTS DIMMER NOT WORKING   K091   


 

 

 

Test results

 

1

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Using the Examiner in the Instrument Panel Node mode, check that there are no errors and that the parameters are present

 

Move on to Step 5

 

1. Impossible to connect with the Instrument Panel control unit

2. Errors present

 

1. Move on to Step 2

2. Continue following the instructions on the diagnostic instrument

 

2

 

ELECTRICAL POWER SUPPLY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the electricity supply to the Instrument Panel Node is correct

 

Move on to Step 3

 

Fault in positive electrical power supply and/or earth

 

Replace the defective component (in the case of a fuse, find out what caused it to blow)

 

3

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected see Wiring Diagram

 See E4010 INSTRUMENT PANEL

 

Move on to Step 4

 

Electrical connections not working

 

Restore the damaged electrical connections

 

4

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Use an Examiner to check the possibility of connection to the Instrument Panel Node

 

Move on to Step 6

 

Impossible to connect with the Instrument Panel control unit

 

Replace the Instrument Panel

 Op. 5560B10 CONTROL PANEL - R+R

 

5

 

ACTIVE DIAGNOSIS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

With the Examiner in Instrument Panel Node mode, check that the instrument panel light is correctly activated in Active Diagnosis

 

Move on to Step 6

 

The panel lighting is not activated

 

Replace the Instrument Panel

 Op. 5560B10 CONTROL PANEL - R+R

 

6

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Using the Examiner check, in the Body Computer Node ambient, that there are no errors and that the lighting parameter varies

 

End of diagnosis

 

1. Impossible to connect to the Body Computer control unit

2. Errors present

3. The parameters do not change

 

1. Move on to Step 7

2. Continue following the instructions on the diagnostic instrument

3. Move on to Step 10

 

7

 

ELECTRICAL POWER SUPPLY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the Body Computer power supply is correct

 

Move on to Step 8

 

Fault in positive electrical power supply and/or earth

 

Replace the defective component (in the case of a fuse, find out what caused it to blow)

 

8

 

CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the continuity of the wiring between the control panel and the Body Computer Node

 See E4010 INSTRUMENT PANEL

Also check that the Menu +/- buttons are working properly

 See Test 5560BX CONTROL PANEL OPERATION CHECK

 

Move on to Step 9

 

1. Electrical connections not working

2. Buttons faulty

 

1. Restore the damaged electrical connections

2. Replace the control panel

 Op. 7040A82 SWITCH UNIT ON LEFT SIDE OF DASHBOARD - R.R.

 

9

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Use an Examiner to check the possibility of connection to the Body Computer Node

 

End of diagnosis

 

Impossible to connect to the Body Computer control unit

 

Replace the Body Computer Node

 Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.

With the ignition ON and the side lights on, the instruments light up, but the brightness remains constant when the controls ar operated

the side lights work properly