145 - MiTo   1.4 16v TJet   DOORS OPEN CHECK WARNING LIGHT/SYMBOL ON   K009   


 

 

 

Test results

 

0

 

PRELIMINARY CHECKS

 

All OK

 

Problems encountered

 

Operation

 

 

Check that both the doors are properly shut

 

Move on to Step 1

 

Doors not properly shut

 

Shut the doors properly

 

1

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Using the Examiner in the Instrument Panel Node mode, check that there are no errors and that the parameters are present

 

Move on to Step 2

 

1. Impossible to connect with the Instrument Panel control unit

2. Errors present

 

1. Move on to Step 2

2. Continue following the instructions on the diagnostic instrument

 

2

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Using the Examiner check, in the Body Computer Node ambient, that there are no errors and that the door status parameters vary

 

Move on to Step 4

 

The parameters do not change

 

Move on to Step 3

 

3

 

ELECTRICAL CONNECTION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

- Check that the door switches in the geared motors are working properly

- Check the insulation to earth of the connection between the door switches and the Body Computer

 See E3040 CENTRAL LOCKING

 

Move on to Step 4

 

1. Switches defective

2. Wiring with imperfect insulation to earth

 

1. Replace the switches

2. Restore wiring insulation

 

4

 

ACTIVE DIAGNOSIS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

With the Examiner in the Instrument Panel Node ambient check that the doors open check warning light is correctly activated in Active Diagnosis

 

Move on to Step 5

 

The doors open check warning light is not activated

 

Replace the Instrument Panel

 Op. 5560B10 CONTROL PANEL - R+R

 

5

 

CORRECT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the fault is no longer present

 

End of diagnosis

 

Fault persists

 

Replace the Body Computer

 Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.

After having carried out the initial test, the doors open check warning light in the "Instrument Panel Node" remains on constantly