145 - MiTo   1.4 16v TJet   REV COUNTER NOT WORKING   K001   


 

1

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

ALL OK

 

PROBLEMS ENCOUNTERED

 

ACTION

 

 

Connect the Examiner to the diagnostic socket.

Check that there are no faults in the instrument panel

 

Move on to Step 2

 

Errors present

 

Continue following the instructions provided by the diagnostic equipment

 

2

 

ELECTRICAL CIRCUIT CHECK

 

ALL OK

 

PROBLEMS ENCOUNTERED

 

ACTION

 

 

Check connections between instrument panel, Body Computer and engine management control unit

 See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT

 

Move on to Step 3

 

Wiring defective

 

Repair/replace the wiring.

 

3

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

ALL OK

 

PROBLEMS ENCOUNTERED

 

ACTION

 

 

Keeping the Examiner equipment connected to the diagnostic socket, check the operation of the display in active diagnosis

 

End of diagnosis

 

Rev counter not working due to stepper motor failure

 

Replace the Instrument Panel

 Op. 5560B10 CONTROL PANEL - R+R

With the engine running, the rev counter does not work or works irregularly.