145 - MiTo   1.4 16v TJet   IGNITION SWITCH NOT WORKING   B001   


 

 

 

Test results

 

0

 

PRELIMINARY CHECKS

 

All OK

 

Problems encountered

 

Operation

 

 

First of all, check the efficiency of the battery

 

Move on to Step 1

 

Battery run down

 

Recharge the battery

 

Battery run down and cannot be recharged

 

Replace the battery

 

1

 

SYSTEM CURRENT DISPERSION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check using the

 See Test 5530BD CHECK ON ELECTRICAL SYSTEM CURRENT ABSORPTION WITH NO LOAD

any current dispersions on the system.

Check that the alternator is working properly by carrying out the

 See Test 5530AB ALTERNATOR OPERATION CHECK

 

Move on to Step 2

 

Dispersion for services that are live with everything turned off

 

Eliminate current dispersion

 

Faulty alternator regulator

 

Replace regulator

 Op. 5530A24 ALTERNATOR VOLTAGE REGULATOR - R.R. WITH ALTERNATOR REMOVED

 

Alternator defective

 

Replace alternator

 Op. 5530A10 ALTERNATOR - R.R.

 

2

 

BATTERY CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the following, in order:

- correct fastening and earth connection of the negative battery terminal;

- correct fastening of positive battery terminal and all leads connected to it;

- no oxidation at the earth point for the negative battery lead

Check for any current dispersions on the system

 

Move on to Step 3

 

Connections not correct

 

Restore the correct connections

 See E1010 POWER SUPPLY

 

Earth lead damaged

 

Replace the lead

 

Lead between battery and starter motor damaged

 

Replace the lead

 

3

 

IGNITION SWITCH CIRCUIT CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the correct power supply is reaching the ignition switch

 See E5010 STARTING AND RECHARING

 

Move on to Step 4

 

Connections not correct

 

Restore the connections between the battery and the ignition switch.

 

4

 

KEY LOCK BARREL CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the key lock barrel and that it is working properly

 

Move on to Step 5

 

Lock barrel faulty

 

Repair or replace the lock barrel

 Op. 5520A14 IGNITION KEY LOCK BARREL - R+R

 

5

 

IGNITION SWITCH CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the ignition switch and make sure that it is working properly

 

End of diagnosis

 

Ignition switch faulty

 

Repair or replace the ignition switch

 Op. 5520A10 IGNITION SWITCH ASSEMBLY - R+R

Nothing happens when the ignition is turned to MAR. The starter motor does not turn, the instruments do not light up