145 - MiTo   1.4 16v TJet   WASTE GATE SUPERCHARGING PRESSURE ADJUSTMENT SOLENOID VALVE - R.R.   1064B38   

Detail     Detail

Removing ( Refitting )

   Op. 1048A23 COLD AIR INTAKE FOR AIR FILTER - R.R.


Enlarge the image


1. Adjust the retaining clip and remove the waste gate solenoid valve from the fan support.


Enlarge the image


1. Disonnect the electrical connection for the waste gate solenoid valve.

 

 

Description

 

Connector

 

1

 

Waste gate solenoid valve

 

   See L037 WASTE GATE SOLENOID VALVE


Enlarge the image


1. Loosen the bands, disconnect the air pipes and remove the waste gate solenoid valve.

Refitting ( Removing )

- Connect the air pipes to the waste Gate solenoid valve and tighten the bands.

- Connect the electrical connection for the waste gate solenoid valve.

- Place the waste gate solenoid valve in position and check that the retaining clip is inserted in the fan support.

    Op. 1048A23 COLD AIR INTAKE FOR AIR FILTER - R.R.