145 - MiTo   1.4 16v TJet   ALTERNATOR TERMINAL "D+" CHECK   5530AA   


- Connect the Examiner in Voltmeter mode with the positive terminal to terminal D+ of the alternator and the negative earthed.

- With the ignition on, ensure that the measured voltage is less than 5.5 Volts and that the generator warning light on the panel is on.

- If the voltage is interrupted, the alternator is inefficient and should be replaced.

- Start the engine and check, with voltage D+ greater than 5.5 Volts, that the generator warning light on the panel goes off and a correct battery recharging indication is displayed.