5505 1 631 RA BODY COMPUTER - START&STOP
Occasional restarting of the engine - Service Solution


FAULT COMPLAINED OF

Incorrect operation of the Start&Stop system; after the correct stopping, occasionally the engine restarts automatically without any action by the driver.

TECHNICAL CAUSE

Incorrect Body Computer software parameters.

OPERATIONS IN NETWORK

Network behaviour standards towards the Customer

-If the claimed fault is confirmed, reassure the Customer that it can be solved by reprogramming the Body Computer.-After the intervention, check the work done and make sure that the Customer is satisfied.

Service Solution

If the customer''s claimed fault is confirmed, reprogramme the Body Computer control unit using the new software CD Flash 6.00.0 (or higher) available on the Examiner Web according to the Operating Cycle below.

OPERATION CYCLE

If the claimed fault is found, use Examiner with release 7.80.1 (or higher), to reprogramme the Body Computer using CD Flash 6.00.0 (or higher) available from Examiner Web.

The vehicle battery must be in full charge conditions or supported by a battery charger/booster battery so as to ensure a rated voltage of 12 V, during reprogramming.

Control unit codes

The following tables show the hardware (HW) and software (SW) codes of the Body Computer Delphi (EP), before and after reprogramming.

1.4 16v - 1.4 16v Turbo (Tjet) - 1.3 Mjet - 1.6 Mjet with Xenon headlamps

 

Before programming, the control unit must have the following data

 

HW number

 

HW version

 

SW number

 

SW version

 

FI64BC03RL3

 

03

 

28220426

 

0707

 

After programming, the control unit must have the following data

 

HW number

 

HW version

 

SW number

 

SW version

 

FI64BC03RL3

 

03

 

28220426

 

070A

1.4 16v - 1.4 16v Turbo (Tjet) - 1.3 Mjet - 1.6 Mjet without Xenon headlamps

 

Before programming, the control unit must have the following data

 

HW number

 

HW version

 

SW number

 

SW version

 

FI64BC03RL2

 

03

 

28220426

 

0707

 

After programming, the control unit must have the following data

 

HW number

 

HW version

 

SW number

 

SW version

 

FI64BC03RL2

 

03

 

28220426

 

070A

CLAIM REPORT DATA

 

Version

 

Operation

 

Piece

 

Fault

 

Position

 

Time allowance

 

All models in question

 

5505163

 

1

 

RA

 

-

 

0.30