Copyright By Fiat Group Automobiles S.p.A. - Printed 18/06/2009


Alfa MiTo


All versions with anti-theft option
55
09.09
5580 0 000 AA ALARM
Fault indication - Network Information


FAULT COMPLAINED OF

During the alarm system engagement/release, an unusual sound and/or visual warning is displayed and, depending on the situations, the "alarm not available" message is displayed.

OPERATIONS IN NETWORK

In case of claims, check the operation and conditions of the alarm system components, shown in Fig. 1. The sensors on doors, boot and especially that on the engine bonnet lock (A) - Fig. 2:

-are intact-have been correctly fitted-the electrical connections are intact and correct

Fig. 1



    Key

    1 - Body Computer

    2 - Switch on engine bonnet

    3 - Siren

    4 - Ultrasound/antitilt sensors

    5 - Switch on luggage compartment

    6 - Switch on doors

    7 - Remote control

    Fig. 2 – Sensor on engine bonnet lock



      To check the operation and conditions of the alarm system, refer to the diagnostic sheet A033 and to the wiring diagram E7015 in the Service Manual.