P0017-76 |
Alignment inlet camshaft / crankshaft - Wrong mounting position |
|
|
P0033-11 |
Dump valve turbo - Circuit short to ground |
|
|
P0033-12 |
Dump valve turbo - Circuit short to battery |
|
|
P0033-13 |
Dump valve turbo - Circuit open |
|
|
P0039-73 |
Turbo dump valve - Actuator stuck closed |
|
|
P0087-64 |
LPG rail gas pressure low - Signal plausibility failure |
|
|
P0087-72 |
LPG rail gas pressure low - Actuator stuck open |
|
|
P0087-7A |
LPG rail gas pressure low - Fluid leak or seal failure |
|
|
P0088-72 |
LPG rail gas pressure high - Actuator stuck open |
|
|
P0090-22 |
LPG rail gas pressure high - Signal amplitude > maximum |
|
|
P0105-11 |
Intake manifold pressure sensor (Electrical test) - Circuit short to ground |
|
|
P0105-15 |
Intake manifold pressure sensor (Electrical test) - Circuit short to battery or open |
|
|
P0106-21 |
Manifold pressure sensor - Signal amplitude |
|
|
P0106-22 |
Manifold pressure sensor - Signal amplitude >maximum |
|
|
P0106-23 |
Manifold pressure sensor - Signal stuck low |
|
|
P0106-24 |
Manifold pressure sensor - Signal stuck high |
|
|
P0106-62 |
Manifold pressure sensor - Signal compare failure |
|
|
P0106-64 |
Manifold pressure sensor - Signal plausibility failure |
|
|
P0110-11 |
Engine air temperature sensor - Circuit short to ground |
|
|
P0110-15 |
Engine air temperature sensor - Circuit short to battery or open |
|
|
P0111-85 |
Engine air temperature sensor - Signal above allowable range |
|
|
P0115-11 |
Engine coolant temperature sensor (Electrical test) - Circuit short to ground |
|
|
P0115-15 |
Engine coolant temperature sensor (Electrical test) - Circuit short to battery or open |
|
|
P0116-28 |
Engine coolant temperature sensor - Signal bias level out of range/zero adjustment failure |
|
|
P0116-85 |
Engine coolant temperature sensor - Signal above allowable range |
|
|
P0120-12 |
Accelerator pedal potentiometer 1 - Circuit short to battery |
|
|
P0120-14 |
Accelerator pedal potentiometer 1 - Circuit short to ground or open |
|
|
P0120-62 |
Accelerator pedal potentiometer 1 - Signal compare failure |
|
|
P0121-12 |
Throttle potentiometer sensor 1 - Circuit short to battery |
|
|
P0121-14 |
Throttle potentiometer sensor 1 - Circuit short to ground or open |
|
|
P0121-62 |
Throttle potentiometer sensor 1 - Signal compare failure |
|
|
P0130-11 |
Upstream lambda probe (Electrical test) - Circuit short to ground |
|
|
P0130-12 |
Upstream lambda probe (Electrical test) - Circuit short to battery |
|
|
P0130-13 |
Upstream lambda probe (Electrical test) - Circuit open |
|
|
P0130-62 |
Upstream lambda probe (Electrical test) - Signal compare failure |
|
|
P0133-26 |
Upstream lambda probe (Functional test) - Signal rate of change below threshold |
|
|
P0135-11 |
Upstream lambda probe heater power stage - Circuit short to ground |
|
|
P0135-12 |
Upstream lambda probe heater power stage - Circuit short to battery |
|
|
P0135-13 |
Upstream lambda probe heater power stage - Circuit open |
|
|
P0136-11 |
Downstream lambda probe - Circuit short to ground |
|
|
P0136-12 |
Downstream lambda probe - Circuit short to battery |
|
|
P0136-13 |
Downstream lambda probe - Circuit open |
|
|
P0136-62 |
Downstream lambda probe - Signal compare failure |
|
|
P0139-16 |
Downstream lambda probe - Circuit voltage below threshold |
|
|
P0139-17 |
Downstream lambda probe - Circuit voltage above threshold |
|
|
P013A-36 |
Downstream lambda probe - Signal frequency too low |
|
|
P0141-11 |
Downstream lambda probe heater - Circuit short to ground |
|
|
P0141-12 |
Downstream lambda probe heater - Circuit short to battery |
|
|
P0141-13 |
Downstream lambda probe heater - Circuit open |
|
|
P0171-16 |
Multiplicative Adaptation Correction of Lambda Control in LPG mode - Circuit voltage below threshold |
|
|
P0171-17 |
Multiplicative Adaptation Correction of Lambda Control in LPG mode - Circuit voltage above threshold |
|
|
P0172-16 |
Additive adaption correction of Lambda in LPG mode - Circuit voltage below threshold |
|
|
P0172-17 |
Additive adaption correction of Lambda in LPG mode - Circuit voltage above threshold |
|
|
P0191-11 |
LPG fuel rail pressure - Circuit short to ground |
|
|
P0191-15 |
LPG fuel rail pressure - Circuit short to battery or open |
|
|
P0201-11 |
Injector 1 command - Circuit short to ground |
|
|
P0201-12 |
Injector 1 command - Circuit short to battery |
|
|
P0201-13 |
Injector 1 command - Circuit open |
|
|
P0202-11 |
Injector 2 command - Circuit short to ground |
|
|
P0202-12 |
Injector 2 command - Circuit short to battery |
|
|
P0202-13 |
Injector 2 command - Circuit open |
|
|
P0203-11 |
Injector 3 command - Circuit short to ground |
|
|
P0203-12 |
Injector 3 command - Circuit short to battery |
|
|
P0203-13 |
Injector 3 command - Circuit open |
|
|
P0204-11 |
Injector 4 command - Circuit short to ground |
|
|
P0204-12 |
Injector 4 command - Circuit short to battery |
|
|
P0204-13 |
Injector 4 command - Circuit open |
|
|
P0219-68 |
Engine overspeed recognition - Event information |
|
|
P0220-12 |
Accelerator pedal potentiometer 2 - Circuit short to battery |
|
|
P0220-14 |
Accelerator pedal potentiometer 2 - Circuit short to ground or open |
|
|
P0221-12 |
Throttle potentiometer sensor 2 - Circuit short to battery |
|
|
P0221-14 |
Throttle potentiometer sensor 2 - Circuit short to ground or open |
|
|
P0221-62 |
Throttle potentiometer sensor 2 - Signal compare failure |
|
|
P0230-11 |
Fuel pump relay command - Circuit short to ground |
|
|
P0230-12 |
Fuel pump relay command - Circuit short to battery |
|
|
P0230-13 |
Fuel pump relay command - Circuit open |
|
|
P0235-11 |
Pressure sensor upstream throttle valve - Circuit short to ground |
|
|
P0235-15 |
Pressure sensor upstream throttle valve - Circuit short to battery or open |
|
|
P0236-25 |
Manifold pressure sensor - Signal shape/waveform failure |
|
|
P0236-26 |
Manifold pressure sensor - Signal rate of change below threshold |
|
|
P0236-27 |
Manifold pressure sensor - Signal rate of change above threshold |
|
|
P0236-29 |
Manifold pressure sensor - Signal invalid |
|
|
P0240-72 |
Turbo boost actuator - Actuator stuck open |
|
|
P0240-79 |
Turbo boost actuator - Mechanical linkage failure |
|
|
P0243-11 |
Waste gate valve - Circuit short to ground |
|
|
P0243-12 |
Waste gate valve - Circuit short to battery |
|
|
P0243-13 |
Waste gate valve - Circuit open |
|
|
P0300-92 |
Misfire random - Performance or incorrect operation |
|
|
P0301-92 |
Misfire cylinder 1 - Performance or incorrect operation |
|
|
P0302-92 |
Misfire cylinder 2 - Performance or incorrect operation |
|
|
P0303-92 |
Misfire cylinder 3 - Performance or incorrect operation |
|
|
P0304-92 |
Misfire cylinder 4 - Performance or incorrect operation |
|
|
P0325-36 |
Knock sensor - Signal frequency too low |
|
|
P0325-37 |
Knock sensor - Signal frequency too high |
|
|
P0327-11 |
Knock sensors cylinder 3 + 4 - Circuit short to ground |
|
|
P0327-12 |
Knock sensors cylinder 3 + 4 - Circuit short to battery |
|
|
P0328-11 |
Knock sensors cylinder 3 + 4 - Circuit short to ground |
|
|
P0328-12 |
Knock sensors cylinder 3 + 4 - Circuit short to battery |
|
|
P0335-62 |
Engine speed sensor - Signal compare failure |
|
|
P0336-29 |
Engine speed sensor - Signal signal invalid |
|
|
P0340-11 |
Camshaft sensor - Circuit short to ground |
|
|
P0340-15 |
Camshaft sensor - Circuit short to battery or open |
|
|
P0340-62 |
Camshaft sensor - Signal compare failure |
|
|
P0420-62 |
Catalyst efficiency - Signal compare failure |
|
|
P0441-72 |
Purge control valve - Actuator stuck open |
|
|
P0441-73 |
Purge control valve - Actuator stuck closed |
|
|
P0443-11 |
Purge canister valve - Circuit short to ground |
|
|
P0443-12 |
Purge canister valve - Circuit short to battery |
|
|
P0443-13 |
Purge canister valve - Circuit open |
|
|
P0460-86 |
Fuel level - Signal invalid |
|
|
P0480-11 |
Cooling fan 1 - Circuit short to ground |
|
|
P0480-12 |
Cooling fan 1 - Circuit short to battery |
|
|
P0480-13 |
Cooling fan 1 - Circuit open |
|
|
P0480-4B |
Cooling fan 1 - Over temperature |
|
|
P0481-11 |
Cooling fan 2 - Circuit short to ground |
|
|
P0481-12 |
Cooling fan 2 - Circuit short to battery |
|
|
P0481-13 |
Cooling fan 2 - Circuit open |
|
|
P0481-4B |
Cooling fan 2 - Over temperature |
|
|
P0500-68 |
Vehicle speed - Event information |
|
|
P0503-64 |
Vehicle speed - Signal plausibility failure |
|
|
P0504-13 |
Brake pedal switch - Circuit open |
|
|
P0504-62 |
Brake pedal switch - Signal compare failure |
|
|
P0504-67 |
Brake pedal switch - Signal incorrect after event |
|
|
P0504-82 |
Brake pedal switch - Alive/sequence counter incorrect/not updated |
|
|
P0505-16 |
Idle control system - Circuit voltage below threshold |
|
|
P0505-17 |
Idle control system - Circuit voltage above threshold |
|
|
P0520-67 |
Oil pressure switch - Signal incorrect after event |
|
|
P0530-12 |
Air conditioner pressure sensor - Circuit short to battery |
|
|
P0530-14 |
Air conditioner pressure sensor - Circuit short to ground or open |
|
|
P0560-16 |
Battery voltage - Circuit voltage below threshold |
|
|
P0560-17 |
Battery voltage - Circuit voltage above threshold |
|
|
P0564-86 |
Cruise control - Signal invalid |
|
|
P0576-62 |
Cruise control disabled for high deceleration - Signal compare failure |
|
|
P0579-62 |
Cruise control anomalies (disable for high acceleration) - Signal compare failure |
|
|
P0579-68 |
Cruise control anomalies (disable for high acceleration) - Event information |
|
|
P0607-96 |
Control unit faulty (Microprocessor) - Component internal failure |
|
|
P0608-22 |
Control unit faulty (Internal component) - Signal amplitude >maximum |
|
|
P0608-29 |
Control unit faulty (Internal component) - Signal signal invalid |
|
|
P060B-04 |
A/D converter - System Internal Failures |
|
|
P060B-47 |
A/D converter - Watchdog/safety µC failure |
|
|
P060D-96 |
Accelerator pedal voltage - Component internal failure |
|
|
P0610-62 |
Control unit faulty (Internal component) - Signal compare failure |
|
|
P0621-11 |
Alternator signal electrical failure - Circuit short to ground |
|
|
P0621-15 |
Alternator signal electrical failure - Circuit short to battery or open |
|
|
P0638-13 |
Motorized throttle valve power stage - Circuit open |
|
|
P0638-29 |
Motorized throttle valve power stage - Signal signal invalid |
|
|
P0638-86 |
Motorized throttle valve power stage - Signal invalid |
|
|
P0638-98 |
Motorized throttle valve power stage - Component or system over temperature |
|
|
P0645-11 |
Compressor air conditioner relay - Circuit short to ground |
|
|
P0645-12 |
Compressor air conditioner relay - Circuit short to battery |
|
|
P0645-13 |
Compressor air conditioner relay - Circuit open |
|
|
P0645-4B |
Compressor air conditioner relay - Over temperature |
|
|
P0805-12 |
Clutch pedal position sensor (MT application) - Circuit short to battery |
|
|
P0805-14 |
Clutch pedal position sensor (MT application) - Circuit short to ground or open |
|
|
P0806-64 |
Clutch pedal position sensor (MT application) - Signal plausibility failure |
|
|
P080A-55 |
Clutch position not learned (MT application) - Not configured |
|
|
P080A-62 |
Clutch position not learned (MT application) - Signal compare failure |
|
|
P0812-12 |
Reverse gear switch (MT application) - Circuit short to battery |
|
|
P0A0F-23 |
Engine not running in LPG mode - Signal stuck low |
|
|
P0A0F-24 |
Engine not running in LPG mode - Signal stuck high |
|
|
P0A0F-64 |
Engine not running in LPG mode - Signal plausibility failure |
|
|
P1000-92 |
LPG cylinder misfire detected - Performance or incorrect operation |
|
|
P1001-92 |
LPG cylinder 1 misfire detected - Performance or incorrect operation |
|
|
P1002-92 |
LPG cylinder 2 misfire detected - Performance or incorrect operation |
|
|
P1003-92 |
LPG cylinder 3 misfire detected - Performance or incorrect operation |
|
|
P1004-92 |
LPG cylinder 4 misfire detected - Performance or incorrect operation |
|
|
P1080-11 |
LPG rail temperature sensor - Circuit short to ground |
|
|
P1080-15 |
LPG rail temperature sensor - Circuit short to battery or open |
|
|
P1088-11 |
LPG tank level circuit - Circuit short to ground |
|
|
P1088-15 |
LPG tank level circuit - Circuit short to battery or open |
|
|
P1135-1B |
Upstream lambda heater - Circuit resistance above threshold |
|
|
P1141-1B |
Upstream lambda heater - Circuit resistance above threshold |
|
|
P1171-16 |
Additive adaption correction of lambda - Circuit voltage below threshold |
|
|
P1171-17 |
Additive adaption correction of lambda - Circuit voltage above threshold |
|
|
P1172-16 |
Multiplicative adaptation correction of lambda control - Circuit voltage below threshold |
|
|
P1172-17 |
Multiplicative adaptation correction of lambda control - Circuit voltage above threshold |
|
|
P1200-62 |
Injector diagnosis data validity (Injectors electric diagnosis by SDU not guaranteed) - Signal plausibility failure |
|
|
P1201-11 |
LPG Injector circuit Cylinder 1 (ECU side) - Circuit short to ground |
|
|
P1201-12 |
LPG Injector circuit Cylinder 1 (ECU side) - Circuit short to battery |
|
|
P1201-13 |
LPG Injector circuit Cylinder 1 (ECU side) - Open circuit |
|
|
P1202-11 |
LPG Injector circuit Cylinder 2 (ECU side) - Circuit short to ground |
|
|
P1202-12 |
LPG Injector circuit Cylinder 2 (ECU side) - Circuit short to battery |
|
|
P1202-13 |
LPG Injector circuit Cylinder 2 (ECU side) - Open circuit |
|
|
P1203-11 |
LPG Injector circuit Cylinder 3 (ECU side) - Circuit short to ground |
|
|
P1203-12 |
LPG Injector circuit Cylinder 3 (ECU side) - Circuit short to battery |
|
|
P1203-13 |
LPG Injector circuit Cylinder 3 (ECU side) - Open circuit |
|
|
P1204-11 |
LPG Injector circuit Cylinder 4 (ECU side) - Circuit short to ground |
|
|
P1204-12 |
LPG Injector circuit Cylinder 4 (ECU side) - Circuit short to battery |
|
|
P1204-13 |
LPG Injector circuit Cylinder 4 (ECU side) - Open circuit |
|
|
P1230-11 |
LPG valve relay command - Circuit short to ground |
|
|
P1230-12 |
LPG valve relay command - Circuit short to battery |
|
|
P1230-13 |
LPG valve relay command - Open circuit |
|
|
P1302-29 |
Gear shift self learning - Signal signal invalid |
|
|
P1302-55 |
Gear shift self learning - Not configured |
|
|
P130A-98 |
Misfire detected - Component or system over temperature |
|
|
P1310-29 |
First start power limitation - Signal signal invalid |
|
|
P1325-49 |
Knock sensor - Internal electronic failure |
|
|
P1336-62 |
Engine torque comparison - Signal compare failure |
|
|
P1337-62 |
Engine torque comparison - Signal compare failure |
|
|
P1401-11 |
LPG Injector circuit Cylinder 1 (SDU side) - Circuit short to ground |
|
|
P1401-12 |
LPG Injector circuit Cylinder 1 (SDU side) - Circuit short to battery |
|
|
P1401-13 |
LPG Injector circuit Cylinder 1 (SDU side) - Open circuit |
|
|
P1402-11 |
LPG Injector circuit Cylinder 2 (SDU side) - Circuit short to ground |
|
|
P1402-12 |
LPG Injector circuit Cylinder 2 (SDU side) - Circuit short to battery |
|
|
P1402-13 |
LPG Injector circuit Cylinder 2 (SDU side) - Open circuit |
|
|
P1403-11 |
LPG Injector circuit Cylinder 3 (SDU side) - Circuit short to ground |
|
|
P1403-12 |
LPG Injector circuit Cylinder 3 (SDU side) - Circuit short to battery |
|
|
P1403-13 |
LPG Injector circuit Cylinder 3 (SDU side) - Open circuit |
|
|
P1404-11 |
LPG Injector circuit Cylinder 4 (SDU side) - Circuit short to ground |
|
|
P1404-12 |
LPG Injector circuit Cylinder 4 (SDU side) - Circuit short to battery |
|
|
P1404-13 |
LPG Injector circuit Cylinder 4 (SDU side) - Open circuit |
|
|
P1658-11 |
LPG injectors supply command - Circuit short to ground |
|
|
P1658-12 |
LPG injectors supply command - Circuit short to battery |
|
|
P1658-13 |
LPG injectors supply command - Open circuit |
|
|
P1680-74 |
Motorized throttle self learning (test spring) - Actuator slipping |
|
|
P1682-62 |
Motorized throttle self learning (position deviation) - Signal compare failure |
|
|
P1683-64 |
Motorized throttle self learning (limphome position test) - Signal plausibility failure |
|
|
P1684-16 |
Motorized throttle self learning (control range) - Circuit voltage below threshold |
|
|
P1684-26 |
Motorized throttle self learning (control range) - Signal rate of change below threshold |
|
|
P1686-67 |
Motorized throttle self learning (mechanical stop out of range) - Signal incorrect after event2 |
|
|
P1687-16 |
Motorized throttle self learning (ambient condition) - Circuit voltage below threshold |
|
|
P1687-17 |
Motorized throttle self learning (ambient condition) - Circuit voltage above threshold |
|
|
P1688-62 |
Motorized throttle self learning (mechanical stop out of range) - Signal compare failure |
|
|
P1692-62 |
Safety fuel cut off - Signal compare failure |
|
|
P1693-62 |
Engine speed - Signal compare failure |
|
|
P1696-61 |
Ignition angle - Signal calculation failure |
|
|
P1696-62 |
Ignition angle - Signal compare failure |
|
|
P1697-55 |
Variant coding - Not configured |
|
|
P2097-16 |
Upstream lambda probe 1 (plausibility check) - Circuit voltage below threshold |
|
|
P2097-17 |
Upstream lambda probe 1 (plausibility check) - Circuit voltage above threshold |
|
|
P2226-11 |
Atmospheric air pressure sensor - Circuit short to ground |
|
|
P2226-15 |
Atmospheric air pressure sensor - Circuit short to battery or open |
|
|
P2227-21 |
Atmospherical pressure at key on (Functional test) - Signal amplitude |
|
|
P2227-22 |
Atmospherical pressure at key on (Functional test) - Signal amplitude >maximum |
|
|
P2227-62 |
Atmospherical pressure at key on (Functional test) - Signal compare failure |
|
|
P2227-64 |
Atmospherical pressure at key on (Functional test) - Signal plausibility failure |
|
|
P2299-62 |
Plausibility check brake/acceleration - Signal compare failure |
|
|
U0001-87 |
Engine Control Module (ECM) CAN transmission - Missing message |
|
|
U0001-88 |
Engine Control Module (ECM) CAN transmission - Bus off |
|
|
U0405-81 |
Invalid Data Received From Cruise Control Module - Invalid serial data received |
|
|
U0405-83 |
Invalid Data Received From Cruise Control Module - Value of signal protection calculation incorrect |
|
|
U0405-86 |
Invalid Data Received From Cruise Control Module - Signal invalid |
|
|
U0409-87 |
Smart Driver Unit status - Node absent |
|
|
U0422-81 |
Fire Prevention System status (FPS) from Body Control Module (BCM) - Invalid serial data received |
|
|
U0422-82 |
Fire Prevention System status (FPS) from Body Control Module (BCM) - Performance or incorrect operation |
|
|
U0422-8F |
Fire Prevention System status (FPS) from Body Control Module (BCM) - Erratic |
|
|
U0426-51 |
Immobilizer - Not programmed |
|
|
U0426-62 |
Immobilizer - Signal compare failure |
|
|
U0426-63 |
Immobilizer - Circuit component protection time out |
|
|
U0426-68 |
Immobilizer - Event information |
|
|
U0427-68 |
Fire Prevention System (FPS) - Event information |
|
|
U0431-64 |
Engine Control Module (ECM) time off - Signal plausibility failure |
|
|
U0431-87 |
Engine Control Module (ECM) time off - Missing message |
|
|
U1409-92 |
Smart Driver Unit status - Performance or incorrect operation |
|
|
U1426-63 |
Immobilizer - Circuit component protection timeout |
|
|
U1700-87 |
Body Computer Module (BCM) CAN trasmission - Missing message |
|
|
U1700-92 |
Body Computer Module (BCM) CAN trasmission - Performance or incorrect operation |
|
|
U1702-87 |
Powersteering CAN trasmission - Missing message |
|
|
U1706-87 |
Brake System Module (BSM) CAN trasmission - Missing message |
|
|
U1706-92 |
Brake System Module (BSM) CAN trasmission - Performance or incorrect operation |
|
|
U1902-82 |
Brake System Module (BSM) CAN trasmission - Alive/sequence counter incorrect/not updated |
|
|
U1902-83 |
Brake System Module (BSM) CAN trasmission - Value of signal protection calculation incorrect |