145 - MiTo   1.4 16v TJet   Ignition angle - Signal calculation failure   P1696-61   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

CONTROL UNIT UPDATE CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Powertrain Control Module

 

Check that the Powertrain Control Module is updated correctly

 

Go to Step 2

 

Powertrain Control Module software incorrectly updated

 

Update the Powertrain Control Module using the correct software

 

2

 

COMPONENT CONCERNED

 

POWERTRAIN CONTROL MODULE OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Powertrain Control Module

 

Check that the Powertrain Control Module is working correctly

 

End of diagnosis

 

Incorrect operation of Powertrain Control Module

 

Replace the Powertrain Control Module

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R