145 - MiTo   1.4 16v TJet   Compressor air conditioner relay - Circuit short to battery   P0645-12   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

POWERTRAIN CONTROL MODULE AND AIR CONDITIONING COMPRESSOR RELAY ELECTRICAL CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Air conditioning compressor relay and Powertrain Control Module connections

 

Check for loose connections on the Powertrain Control Module or on the air conditioning compressor relay

 

Go to Step 2

 

Presence of loose connections

 

Restore the correct connections

 

2

 

COMPONENT CONCERNED

 

WIRING CHECK BETWEEN POWERTRAIN CONTROL MODULE AND AIR CONDITIONING COMPRESSOR RELAY

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Wiring between Powertrain Control Module and air conditioning compressor relay

 

Check for a short circuit to battery on the wiring between pin 29 of the Powertrain Control Module and the air conditioning compressor relay

 

End of diagnosis

 

Presence of short circuit to battery on wiring

 

Restore the correct wiring insulation to battery