145 - MiTo   1.4 16v TJet   Cooling fan 1 - Over temperature   P0480-4B   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

FAN RELAY AND POWERTRAIN CONTROL MODULE CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Powertrain Control Module and fan 1 relay connections

 

Check for the presence of loose connections on the solenoid valve relay and the Powertrain Control Module

 

Go to Step 2

 

Presence of loose connections

 

Restore the correct connections

 

2

 

COMPONENT CONCERNED

 

WIRING CHECK BETWEEN SOLENOID VALVE RELAY AND POWERTRAIN CONTROL MODULE

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Wiring between fan 1 relay and Powertrain Control Module

 

Check the continuity of the wiring between the fan relay and pin 39 of the Powertrain Control Module

 

Go to Step 3

 

Breaks in the wiring continuity

 

Restore the correct continuity of the wiring

 

3

 

COMPONENT CONCERNED

 

WIRING CHECK BETWEEN FAN RELAY AND POWERTRAIN CONTROL MODULE

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Wiring between fan 1 relay and Powertrain Control Module

 

Check for the presence of a short circuit to earth on the wiring between the fan relay and pin 39 of the Powertrain Control Module

 

Go to Step 4

 

Presence of a short circuit to earth on the wiring

 

Restore the correct wiring insulation to earth

 

4

 

COMPONENT CONCERNED

 

WIRING CHECK BETWEEN FAN RELAY AND POWERTRAIN CONTROL MODULE

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Wiring between fan 1 relay and Powertrain Control Module

 

Check for the presence of a short circuit to battery on the wiring between the fan relay and pin 39 of the Powertrain Control Module

 

End of diagnosis

 

Presence of a short circuit to battery on the wiring

 

Restore the correct wiring insulation to battery