145 - MiTo   1.4 16v TJet   Purge control valve - Actuator stuck open   P0441-72   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

ELECTRICAL CONNECTIONS CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Solenoid valve and Powertrain Control Module connections

 

Check for loose electrical connections at the solenoid and at the Powertrain Control Module.

 

Go to Step 2

 

Presence of loose electrical connections

 

Restore the correct connections.

 

2

 

COMPONENT CONCERNED

 

WIRING CONTINUITY CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Wiring between solenoid valve and Powertrain Control Module

 

Check for breaks in the continuity of the wiring between the solenoid valve and the Powertrain Control Module

 See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT

 

Go to Step 3

 

Breaks in the continuity of the wiring between the solenoid valve and the Powertrain Control Module

 

Restore the correct continuity of the wiring between the solenoid valve and the Powertrain Control Module.

 

3

 

COMPONENT CONCERNED

 

DUCT CONDITION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Solenoid valve

 

Check the condition of the ducts connected to the solenoid.

 

Go to Step 4

 

Presence of faults in the solenoid valve ducts

 

Restore correct operation.

 

4

 

COMPONENT CONCERNED

 

SOLENOID OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Solenoid valve

 

Connect the diagnosis equipment to the Powertrain Control Module to check the correct evaporation valve operation.

 

End of diagnosis

 

Solenoid valve not working properly

 

Replace the solenoid

 Op. 1080E28 PIPE FROM ACTIVE CHARCOAL FILTER TO SOLENOID - R.R.