145 - MiTo   1.4 16v TJet   Upstream lambda probe (Electrical test) - Signal compare failure   P0130-62   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

ELECTRICAL CONNECTIONS CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Connections on oxygen sensor and Powertrain Control Module

 

Check for loose electrical connections at the sensor connector and at the Powertrain Control Module.

 

Go to Step 2

 

Presence of loose electrical connections.

 

Restore the correct connections.

 

2

 

COMPONENT CONCERNED

 

WIRING CONTINUITY CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Oxygen sensor wiring

 

Check for breaks in the wiring continuity caused by oxidised or corroded terminals

 

Go to Step 3

 

Breaks in the wiring continuity.

 

Restore the correct continuity for the wiring.

 

3

 

COMPONENT CONCERNED

 

WIRING INSULATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Oxygen sensor wiring

 

Check the condition of the wiring insulation (check for inversion of signal leads or open circuit at signal leads).

 

Go to Step 4

 

Wiring insulation faulty.

 

Restore correct wiring insulation.

 

4

 

COMPONENT CONCERNED

 

EARTH CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Oxygen sensor wiring

 

Check the condition of the earth connections.

 

Go to Step 5

 

Breaks in the wiring continuity.

 

Restore the correct earth connections.

 

5

 

COMPONENT CONCERNED

 

CHECK ON SEEPAGE IN EXHAUST MANIFOLD

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Exhaust manifold

 

Check for the presence of any seepage in the exhaust manifold.

 

Go to Step 6

 

Seepage inside the exhaust manifold.

 

Restore correct operation

 

6

 

COMPONENT CONCERNED

 

SENSOR CONDITION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Oxygen sensor

 

Check for the presence of any oil or oxidation on the sensitive element or impact to the sensor casing. Also check that it is correctly fitted.

 

Go to Step 7

 

Sensor fouled, contaminated or not correctly installed.

 

Clean the sensor or fit it correctly.

 

7

 

COMPONENT CONCERNED

 

OXYGEN SENSOR OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Oxygen sensor

 

Check that the oxygen sensor is working correctly

 See Test 1080BA Check on the operation of the upstream Lambda sensor

 

End of diagnosis

 

Oxygen sensor not working properly.

 

Replace the upstream oxygen sensor

 Op. 1080B94 FRONT LAMBDA SENSOR TO WITH CATALYTIC CONVERTER - R.R