145 - MiTo   1.4 16v TJet   Linea CAN - Messaggio mancante   U0019-87   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

CAN LINE CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN (Mute)

 

Check the continuity of the CAN line wiring

 

Go to Step 2

 

CAN line wiring interrupted

 

Restore the CAN line continuity

 

2

 

COMPONENT CONCERNED

 

TPMS CONTROL UNIT CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

TPM (Mute)

 

Check that the connector for the TPMS control unit is connected

 

Go to Step 3

 

TPMS control unit connector disconnected

 

Reconnect the TPMS control unit connector

 

3

 

COMPONENT CONCERNED

 

CHECK USING DIAGNOSIS EQUIPMENT

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN (Bus Off)

 

Connect the diagnosis equipment to the car and check whether there are faulty control units on the network

 

Go to Step 4

 

Network control unit faulty (CAN overloaded)

 

Continue as instructed by the diagnosis equipment

 

4

 

COMPONENT CONCERNED

 

CAN LINE CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN (Bus Off)

 

Check the correct insulation of the CAN Low to + battery

 

End of diagnosis

 

Short circuit to + battery

 

Restore insulation to + battery