145 - MiTo   1.4 16v TJet   Gas solenoid valve relay   P1230   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

GAS SOLENOID VALVE RELAY WIRING CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Gas solenoid valve relay wiring

 

Check for a short circuit to earth on the gas solenoid valve relay wiring

 

Go to Step 2

 

Presence of short circuit to earth in the wiring

 

Restore correct insulation to earth

 

2

 

COMPONENT CONCERNED

 

GAS SOLENOID VALVE RELAY WIRING CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Gas solenoid valve relay wiring

 

Check for a short circuit to Vbatt. on the gas solenoid valve relay wiring

 

Go to Step 3

 

Presence of short circuit to Vbatt.

 

Restore correct insulation to +battery

 

3

 

COMPONENT CONCERNED

 

GAS SOLENOID VALVE RELAY WIRING CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Gas solenoid valve relay wiring

 

Check for an open circuit on the gas solenoid valve relay wiring

 

End of diagnosis

 

Presence of open circuit

 

Restore the correct continuity