145 - MiTo   1.4 16v TJet   LPG solenoid valve   P1230   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

LPG SOLENOID VALVE WIRING CHECKS

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

LPG solenoid valve

 

Check for the presence of a short circuit to Vbatt on the solenoid valve wiring

 

Go to Step 2

 

Presence of short circuit to Vbatt.

 

Restore insulation to + battery

 

2

 

COMPONENT CONCERNED

 

LPG solenoid valve wiring checks

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Solenoid valve

 

Check for the presence of an open circuit on the solenoid valve wiring

 

Go to Step 3

 

Presence of open circuit

 

Restore the correct insulation

 

3

 

COMPONENT CONCERNED

 

LPG SOLENOID VALVE WIRING CHECKS

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

LPG solenoid valve

 

Check for the presence of a short circuit to earth on the solenoid valve wiring

 

End of diagnosis

 

Presence of short circuit to earth

 

Restore insulation to earth