145 - MiTo   1.4 16v TJet   Communic. with Clustor (NQS)   U1703   


 

 

 

Test results

 

1

 

INSTRUMENT PANEL NODE CONNECTION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the CAN connections between the instrument panel and the Body Computer are not faulty. In particular, that there are no open circuit or short circuit problems

 See E1050 CAN CONNECTION LINES

 

Go to Step 2

 

There are faulty connections

 

Restore or, if necessary, replace the wiring

 

2

 

BODY COMPUTER POWER SUPPLY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the Body Computer power supply is correct

 

Go to Step 3

 

Power supply not correct

 

Restore the correct power supply.

 

3

 

INSTRUMENT PANEL REPLACEMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Replace the Instrument Panel

 Op. 5560B10 CONTROL PANEL - R+R

and check it is working correctly

 

End of diagnosis

 

The fault persists

 

Go to Step 4

 

4

 

REPLACING THE BODY COMPUTER

 

All OK

 

Problems encountered

 

Operation

 

 

Replace Body Computer

Op. 5505A32

 

End of diagnosis