145 - MiTo   1.4 16v TJet   Internal error   B1005   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

CHECK +30 POWER SUPPLY FUSE OPERATION

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

+30 power supply fuse

 

Check that the +30 power supply fuse works correctly with key off.

 

Go to Step 2

 

Fuse blown

 

Replace the fuse and find out what caused the malfunction.

 

2

 

COMPONENT CONCERNED

 

CONVERGENCE CONTROL UNIT OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Convergence control unit

 

Reprogram the application and all additional SW packages to check whether the component's behaviour is stable

 

End of diagnosis

 

Unstable behaviour of the component

 

Replace the Convergence control unit

 Op. 5570T49 BLUETOOTH ELECTRONIC CONTROL UNIT - R.R.