145 - MiTo   1.4 16v TJet   BUS off   U1602   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

CHECK USING THE EXAMINER

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN

 

Check for control unit errors using the Examiner diagnosis equipment in "CAN information" mode

 

Go to Step 2

 

Network control unit faulty (CAN overloaded)

 

Continue as instructed by the diagnosis equipment

 

2

 

COMPONENT CONCERNED

 

CAN LINE CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN

 

Check the correct insulation of the CAN Low to + battery

 

End of diagnosis

 

Short circuit to + battery

 

Restore insulation to + battery