145 - MiTo   1.4 16v TJet   C-CAN line error   U0001   


 

 

 

 

Test results

 

1

 

COMPONENT CONCERNED

 

CHECK USING DIAGNOSTIC EQUIPMENT

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN

(Bus off)

 

Connect the Examiner diagnosis equipment, enter "CAN information" and check for any control unit errors

 

Go to Step 2

 

Network control unit faulty (CAN overloaded)

 

Continue as instructed by the diagnostic equipment

 

2

 

COMPONENT CONCERNED

 

CAN HIGH ISOLATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN

(Bus off)

 

Check the correct isolation of the CAN High to earth

 

Go to Step 3

 

CAN short circuit to earth

 

Restore insulation to earth

 

3

 

COMPONENT CONCERNED

 

CAN LOW ISOLATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN

(Bus off)

 

Check the insulation of the CAN Low to + battery

 

Go to Step 4

 

Short circuit to + battery

 

Restore insulation to + battery

 

4

 

COMPONENT CONCERNED

 

ENGINE MANAGEMENT CONTROL UNIT CONNECTOR CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

Engine management control unit

(Mute)

 

Check that the connectors for the engine management control unit are connected correctly

 

Go to Step 5

 

Engine management control unit connectors disconnected

 

Restore the correct connection of the engine management control unit

 

5

 

COMPONENT CONCERNED

 

CAN LINE CONTINUITY CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

 

 

CAN line

(Mute)

 

Check the correct continuity of the CAN line

 

End of diagnosis

 

CAN line wiring interrupted

 

Restore the correct wiring of the CAN line