145 - MiTo   1.4 16v TJet   Climate control (NCL)   U1710   


 

 

 

Test results

 

1

 

CONDITIONER CONTROL UNIT CONNECTION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the CAN connections between the conditioner control unit and the Body Computer are not faulty. In particular, that there are no open circuit or short circuit problems

 See E1050 CAN CONNECTION LINES

 

Go to Step 2

 

There are faulty connections

 

Restore or, if necessary, replace the wiring

 

2

 

BODY COMPUTER POWER SUPPLY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the Body Computer power supply is correct.

 

Go to Step 3

 

Power supply not correct

 

Restore the correct power supply.

 

3

 

REPLACING THE AIR CONDITIONING CONTROL UNIT

 

All OK

 

Problems encountered

 

Operation

 

 

Replace the air conditioning control unit

 Op. 5040D15 CONTROL UNIT WITH KNOBS AND BUTTONS FOR DUAL ZONE AIR CONDITIONER - R.R.

and check it is working correctly

 

End of diagnosis

 

The fault persists.

 

Go to Step 4

 

4

 

REPLACING THE BODY COMPUTER

 

All OK

 

Problems encountered

 

Operation

 

 

Replace the Body Computer

 Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.

 

End of diagnosis