145 - MiTo   1.4 16v TJet   Mixture 1 strength (multiplicative)   P1172   


ABOVE UPPER LIMIT (FRA)

 

 

 

Test results

 

1

 

CHECK ON SEEPAGE IN EXHAUST MANIFOLD

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of any seepage in the exhaust manifold.

 

Go to Step 2

 

Seepage inside the exhaust manifold.

 

Restore correct operation

 

2

 

PRESSURE SENSOR CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the pressure sensor is working properly by carrying out the

 See Test 1056BU CHECK ON OPERATION OF PRESSURE SENSOR AND/OR INTAKE AIR TEMPERATURE SENSOR

 

Go to Step 3

 

Pressure sensor not working properly.

 

Replace the pressure sensor

 Op. 1056B54 INTAKE AIR PRESSURE/TEMPERATURE SENSOR - R.R.

 

3

 

SENSOR CONDITION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of any oil or oxidation on the sensitive element or impact to the sensor casing. Also check that it is correctly fitted.

 

Go to Step 4

 

Sensor fouled, contaminated or not correctly installed.

 

Clean the sensor or fit it correctly.

 

4

 

LAMBDA SENSOR OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the Lambda sensor is working properly by performing the

 See Test 1080BA Check on the operation of the upstream Lambda sensor

 

Go to Step 5

 

Lambda sensor not working properly.

 

Replace the Lambda sensor

 Op. 1080B94 FRONT LAMBDA SENSOR TO WITH CATALYTIC CONVERTER - R.R

 

5

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly.

 

End of diagnosis

 

Engine management control unit faulty.

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R

BELOW LOWER LIMIT (FRA)

 

 

 

Test results

 

1

 

CHECK ON SEEPAGE IN EXHAUST MANIFOLD

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of any seepage in the exhaust manifold.

 

Go to Step 2

 

Seepage inside the exhaust manifold.

 

Restore correct operation

 

2

 

PRESSURE SENSOR CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the pressure sensor is working properly by carrying out the

 See Test 1056BU CHECK ON OPERATION OF PRESSURE SENSOR AND/OR INTAKE AIR TEMPERATURE SENSOR

 

Go to Step 3

 

Pressure sensor not working properly.

 

Replace the pressure sensor

 Op. 1056B54 INTAKE AIR PRESSURE/TEMPERATURE SENSOR - R.R.

 

3

 

SENSOR CONDITION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of any oil or oxidation on the sensitive element or impact to the sensor casing. Also check that it is correctly fitted.

 

Go to Step 4

 

Sensor fouled, contaminated or not correctly installed.

 

Clean the sensor or fit it correctly.

 

4

 

LAMBDA SENSOR OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the Lambda sensor is working properly by performing the

 See Test 1080BA Check on the operation of the upstream Lambda sensor

 

Go to Step 5

 

Lambda sensor not working properly.

 

Replace the Lambda sensor

 Op. 1080B94 FRONT LAMBDA SENSOR TO WITH CATALYTIC CONVERTER - R.R

 

5

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly.

 

End of diagnosis

 

Engine management control unit faulty.

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R