145 - MiTo   1.4 16v TJet   Control Unit faulty (Microprocessor)   P0606   


SIGNAL NOT VALID

 

 

 

Test results

 

1

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for loose electrical connections at the battery, at the alternator and at the engine management control unit.

 

Go to Step 2

 

Presence of loose electrical connections.

 

Restore the correct connections.

 

2

 

WIRING CONTINUITY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for breaks in the wiring continuity

 See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT

 

Go to Step 3

 

Breaks in the wiring continuity.

 

Restore the correct continuity for the wiring.

 

3

 

BATTERY CHARGE CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the battery charge using the MIDTRONICS N.° 1806514000 equipment

 

Go to Step 4

 

Battery not working properly. Battery voltage too low when starting.

 

Replace the battery.

 

4

 

CHECK ON CORRECT OPERATION OF MAIN RELAY

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the main relay is working properly

 

Go to Step 5

 

Main relay not working properly.

 

Replace the main relay.

 

5

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly.

 

End of diagnosis

 

Engine management control unit faulty.

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R