145 - MiTo   1.4 16v TJet   Preheating resistance 1 below catal.   P0141   


NO SIGNAL

 

 

 

Test results

 

1

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for loose electrical connections at the sensor connector and at the engine management control unit.

 

Go to Step 2

 

Presence of loose electrical connections.

 

Restore the correct connections.

 

2

 

WIRING CONTINUITY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for breaks in the wiring continuity

 See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT

 

Go to Step 3

 

Breaks in the wiring continuity.

 

Restore the correct continuity for the wiring.

 

3

 

WIRING INSULATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the wiring insulation (short circuit between conductors).

 

Go to Step 4

 

Wiring insulation faulty.

 

Restore correct wiring insulation.

 

4

 

LAMBDA SENSOR OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the Lambda sensor is working properly by performing the

 See Test 1080BD Check on the operation of the downstream Lambda sensor

 

Go to Step 5

 

Lambda sensor not working properly.

 

Replace the Lambda sensor

 Op. 1080B95 REAR LAMBDA SENSOR TO CATALYTIC CONVERTER - R.R

 

5

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly.

 

End of diagnosis

 

Engine management control unit faulty.

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R

ABOVE THRESHOLD

 

 

 

Test results

 

1

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for loose electrical connections at the sensor connector and at the engine management control unit.

 

Go to Step 2

 

Presence of loose electrical connections.

 

Restore the correct connections.

 

2

 

WIRING CONTINUITY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for breaks in the wiring continuity

 See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT

 

Go to Step 3

 

Breaks in the wiring continuity.

 

Restore the correct continuity for the wiring.

 

3

 

WIRING INSULATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the wiring insulation (short circuit between conductors).

 

Go to Step 4

 

Wiring insulation faulty.

 

Restore correct wiring insulation.

 

4

 

LAMBDA SENSOR OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the Lambda sensor is working properly by performing the

 See Test 1080BD Check on the operation of the downstream Lambda sensor

 

Go to Step 5

 

Lambda sensor not working properly.

 

Replace the Lambda sensor

 Op. 1080B95 REAR LAMBDA SENSOR TO CATALYTIC CONVERTER - R.R

 

5

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly.

 

End of diagnosis

 

Engine management control unit faulty.

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R

BELOW THRESHOLD

 

 

 

Test results

 

1

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for loose electrical connections at the sensor connector and at the engine management control unit.

 

Go to Step 2

 

Presence of loose electrical connections.

 

Restore the correct connections.

 

2

 

WIRING CONTINUITY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for breaks in the wiring continuity

 See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT

 

Go to Step 3

 

Breaks in the wiring continuity.

 

Restore the correct continuity for the wiring.

 

3

 

WIRING INSULATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the wiring insulation (short circuit between conductors).

 

Go to Step 4

 

Wiring insulation faulty.

 

Restore correct wiring insulation.

 

4

 

LAMBDA SENSOR OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the Lambda sensor is working properly by performing the

 See Test 1080BD Check on the operation of the downstream Lambda sensor

 

Go to Step 5

 

Lambda sensor not working properly.

 

Replace the Lambda sensor

 Op. 1080B95 REAR LAMBDA SENSOR TO CATALYTIC CONVERTER - R.R

 

5

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly.

 

End of diagnosis

 

Engine management control unit faulty.

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R