145 - MiTo   1.4 16v TJet   Air temperature sensor   P0110   


ABOVE THRESHOLD (short circuit to GND)

 

 

 

Test results

 

1

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for loose electrical connections at the air temperature sensor and at the engine management control unit.

 

Go to Step 2

 

Presence of loose electrical connections.

 

Restore the correct connections.

 

2

 

WIRING CONTINUITY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for breaks in the wiring continuity

 See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT

 

Go to Step 3

 

Breaks in the wiring continuity.

 

Restore the correct continuity for the wiring.

 

3

 

WIRING INSULATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the wiring insulation

 

Go to Step 4

 

Wiring insulation faulty.

 

Restore correct wiring insulation.

 

4

 

EARTH CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the earth connections.

 

Go to Step 5

 

Breaks in the wiring continuity.

 

Restore the correct earth connections.

 

5

 

AIR TEMPERATURE SENSOR OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the air temperature sensor is working properly by carrying out the

 See Test 1056BU CHECK ON OPERATION OF PRESSURE SENSOR AND/OR INTAKE AIR TEMPERATURE SENSOR

 

Go to Step 6

 

Air temperature sensor not working properly.

 

Replace the air temperature sensor

 Op. 1056B54 INTAKE AIR PRESSURE/TEMPERATURE SENSOR - R.R.

 

6

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly.

 

End of diagnosis

 

Engine management control unit faulty.

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R

BELOW THRESHOLD (short circuit to Vbatt, open circuit)

 

 

 

Test results

 

1

 

ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for loose electrical connections at the air temperature sensor and at the engine management control unit.

 

Go to Step 2

 

Presence of loose electrical connections.

 

Restore the correct connections.

 

2

 

WIRING CONTINUITY CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for breaks in the wiring continuity

 See E5030 PETROL ENGINES ELECTRONIC MANAGEMENT

 

Go to Step 3

 

Breaks in the wiring continuity.

 

Restore the correct continuity for the wiring.

 

3

 

WIRING INSULATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the wiring insulation

 

Go to Step 4

 

Wiring insulation faulty.

 

Restore correct wiring insulation.

 

4

 

EARTH CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check the condition of the earth connections.

 

Go to Step 5

 

Breaks in the wiring continuity.

 

Restore the correct earth connections.

 

5

 

AIR TEMPERATURE SENSOR OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the air temperature sensor is working properly by carrying out the

 See Test 1056BU CHECK ON OPERATION OF PRESSURE SENSOR AND/OR INTAKE AIR TEMPERATURE SENSOR

 

Go to Step 6

 

Air temperature sensor not working properly.

 

Replace the air temperature sensor

 Op. 1056B54 INTAKE AIR PRESSURE/TEMPERATURE SENSOR - R.R.

 

6

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly.

 

End of diagnosis

 

Engine management control unit faulty.

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R