145 - MiTo   1.4 16v TJet   Additional heater   U1734   


This error is signalled if the control unit does not detect the additional heater.

 

 

 

Test results

 

1

 

CAN CONTROL UNITS FAULT DIAGNOSIS

 

All OK

 

Problems encountered

 

Operation

 

 

Use the diagnostic tool to test the CAN line control units; specifically check for errors on the additional heater node.

 

Move on to Step 2

 

1. Presence of errors at CAN control units

2. Presence of additional heater errors.

 

1. Continue following the instructions given by the diagnostic equipment.

2. Continue following the instructions given by the diagnostic equipment.

 

2

 

CAN IMPEDANCE CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Detach the body computer connector and check, using the tester, that the control unit side circuit resistance is 120 Ohms like on the connector side

Check the additional heater supply voltage

 

Move on to Step 3

 

1. CAN faulty

2. No additional heater power

 

1. Move on to Step 3

2. Restore the correct power supply.

 

3

 

ELECTRICAL CHECKS

 

All OK

 

Problems encountered

 

Operation

 

 

Check the additional heater wiring harness

 

Move on to Step 4

 

Wiring faulty

 

Restore the correct connection

 

4

 

CORRECT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Use the diagnostic instrument to delete the error and check that the fault is no longer present

 

End of diagnosis

 

The fault persists.

 

Move on to Step 1.