145 - MiTo   1.4 16v TJet   Recirculation motor   B1909   


 

 

 

Test results

 

1

 

AIR RECIRCULATION ACTUATOR ELECTRICAL CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of short circuits to earth or Vbatt.

 See E6020 AIR CONDITIONING

 

End of diagnosis

 

1. Presence of short circuit to earth.

2. Presence of short circuit to Vbatt.

 

1. Restore insulation to earth

2. Restore insulation to + battery

 

2

 

CHECK ON IMPEDIMENTS TO THE ROTATION OF THE ACTUATOR

 

All OK

 

Problems encountered

 

Operation

 

 

Remove the actuator and use the control unit control to ensure that the actuator turns, checking for mechanical impediments to its rotation.

 

End of diagnosis

 

1. The actuator does not turn.

2.Kinematic components or flaps broken/stuck.

 

1. Replace the actuator

 Op. 5040D75 AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R

2. Replace the faulty component.