145 - MiTo   1.4 16v TJet   Right Front Inlet Control (Subfault)   C0014   


The diagnostic equipment signals one or more of the following errors: "C0014 - Right front pressurising valve"

This error is signalled if the ABS solenoid valves cannot be activated. This means that there is an open circuit or short circuit (positive or earth) for the solenoid valves or the solenoid valves connection, that the solenoid valves are close to being short circuited or that the operating circuit is damaged

 

 

 

Test results

 

1

 

ABS CONTROL UNIT REPLACEMENT

 

All OK

 

Problems encountered

 

Operation

 

 

Replace the ABS electrohydraulic control unit

 Op. 3340A12 ABS HYDRAULIC AND ELECTRONIC CONTROL UNIT - R.R.

 

Go to Step 2

 

 

 

2

 

CORRECT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Delete the errors using the diagnostic equipment.

Turn the key OFF and then ON to ensure that the control unit checks whether the errors are still present.

Check that the fault is no longer present

 

End of diagnosis