145 - MiTo   1.4 16v TJet   Low Speed CAN Communication Bus   U0019   


 

 

 

Test results

 

1

 

CAN LINE CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

If the type of error is "MUTE"

Check:

- CAN line continuity

- Instrument panel control unit connector (control unit disconnected from the network)

 See E4010 INSTRUMENT PANEL

 

Go to Step 2

 

1. CAN line wiring interrupted

2. Instrument panel control unit connector

 

1. Restore the CAN line continuity

2. Connect instrument panel connector

 

2

 

CHECK USING THE EXAMINER

 

All OK

 

Problems encountered

 

Operation

 

 

If the type of error is "BUS OFF"

Check for control unit errors using an Examiner in "CAN information" mode

Check the insulation of the CAN High to earth

Check the insulation of the CAN Low to + battery

 

Go to Step 3

 

1. Network control unit faulty (CAN overloaded)

2. CAN short circuit to earth

3. Short circuit to + battery

 

1. Continue as instructed by the diagnosis equipment

2. Restore insulation to earth

3. Restore insulation to + battery

 

3

 

ENGINE CONTROL UNIT CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

If the type of error is "CAN adjustment"

Replace the instrument panel control unit and check that it is working properly

 Op. 5560B10 CONTROL PANEL - R+R

 

End of diagnosis