145 - MiTo   1.4 16v TJet   Turbocharger/Supercharger Bypass Valve Control Circuit   P0033   


BELOW THRESHOLD (short circuit to GND)

 

 

 

Test results

 

1

 

CHECK ON CONNECTIONS AT TURBOCHARGING AIR BY-PASS SOLENOID AND AT ENGINE MANAGEMENT CONTROL UNIT

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of loose connections at the turbocharging air by-pass solenoid and at the engine management control unit

 

Go to Step 2

 

Presence of loose connections

 

Restore the correct connections.

 

2

 

WIRING INSULATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the wiring is correctly insulated

 

Go to Step 3

 

Wiring insulation not correct

 

Restore correct insulation

 

3

 

TURBOCHARGING AIR BY-PASS SOLENOID OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the turbocharging air by-pass solenoid is working properly

 See Test 1064BH CHECK ON OPERATION OF SUPERCHARGING AIR BY-PASS SOLENOID VALVE (SHUT OFF)

 

Go to Step 4

 

Solenoid not working properly.

 

Replace the by-pass solenoid

 Op. 1048B58 TURBOCHARGER AIR BY-PASS VALVE - R.R.

 

4

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly

 

End of diagnosis

 

Engine management control unit not working properly

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R

BELOW THRESHOLD (short circuit to Vbatt)

 

 

 

Test results

 

1

 

CHECK ON CONNECTIONS AT TURBOCHARGING AIR BY-PASS SOLENOID AND AT ENGINE MANAGEMENT CONTROL UNIT

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of loose connections at the turbocharging air by-pass solenoid and at the engine management control unit

 

Go to Step 2

 

Presence of loose connections

 

Restore the correct connections.

 

2

 

WIRING INSULATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the wiring is correctly insulated

 

Go to Step 3

 

Wiring insulation not correct

 

Restore correct insulation

 

3

 

TURBOCHARGING AIR BY-PASS SOLENOID OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the turbocharging air by-pass solenoid is working properly

 See Test 1064BH CHECK ON OPERATION OF SUPERCHARGING AIR BY-PASS SOLENOID VALVE (SHUT OFF)

 

Go to Step 4

 

Solenoid not working properly.

 

Replace the by-pass solenoid

 Op. 1048B58 TURBOCHARGER AIR BY-PASS VALVE - R.R.

 

4

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly

 

End of diagnosis

 

Engine management control unit not working properly

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R

NO SIGNAL (open circuit)

 

 

 

Test results

 

1

 

CHECK ON CONNECTIONS AT TURBOCHARGING AIR BY-PASS SOLENOID AND AT ENGINE MANAGEMENT CONTROL UNIT

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of loose connections at the turbocharging air by-pass solenoid and at the engine management control unit

 

Go to Step 2

 

Presence of loose connections

 

Restore the correct connections.

 

2

 

WIRING INSULATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the wiring is correctly insulated

 

Go to Step 3

 

1. Wiring insulation not correct

2. Breaks in the wiring

 

1. Restore correct insulation

2. Restore the correct wiring.

 

3

 

EARTH CONNECTIONS CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check for the presence of unstable earth connections

 

Go to Step 4

 

Earth connections unstable

 

Restore the correct earth connections.

 

4

 

TURBOCHARGING AIR BY-PASS SOLENOID OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the turbocharging air by-pass solenoid is working properly

 See Test 1064BH CHECK ON OPERATION OF SUPERCHARGING AIR BY-PASS SOLENOID VALVE (SHUT OFF)

 

Go to Step 4

 

Solenoid not working properly.

 

Replace the by-pass solenoid

 Op. 1048B58 TURBOCHARGER AIR BY-PASS VALVE - R.R.

 

5

 

ENGINE MANAGEMENT CONTROL UNIT OPERATION CHECK

 

All OK

 

Problems encountered

 

Operation

 

 

Check that the engine management control unit is working properly

 

End of diagnosis

 

Engine management control unit not working properly

 

Replace the engine management control unit

 Op. 1056B82 INJECTION/IGNITION SYSTEM E.C.U. (ONE) - R + R